Since nobody answered yet, I will make my comment an answer.

I just bought the multimeter "Multimeter Digital MAS830L" because I wanted to learn about electronics.

If you don't know exactly what you are doing, don't play around with mains voltages. It's dangerous and mistakes can be deadly.

The first time (every device as much as I remember was off ?) and it measured Voltage correctly. Second Time, the plug sparkled but nothing serious happened. But the tv was on in that room. So when I did it the third time still with the TV on but on the other room, I've had a sparkle from my multimeter and the Plug together. The electrical switch from the room I was in turned off because of the fusions but I don't specifically understand why it happened.

The on/off state of your TV or any other appliance in your home have nothing to do with what happened.

And I'm pretty sure the polarity doesn't has to do with anything here because when you connect a device you can connect it both ways with the same result.

You are right, the polarity doesn't matter for AC.

I changed it just in case with a 10A fusion

Never change a fuse with a higher rating then given! Then in case of next failure not the fuse might blow, but the next weakest link in your device!

Setting on 600/200 V~

On the pictures the Multimeter has 2 different AC positions 200V and 600V. If you had it on the 200V setting, this might have been a mistake. But the area that looks burned in your picture doesn't look like it should have been from this. enter image description here

Finally it is hard so say, what caused your problem. The meter is rated CAT II. But from the pictures you showed, in my opinion its just CAT I. Except this lousy glass fuse there is no further input protection (I cannot even see a beefy / high power input limit resistor anywhere). This device should not be used on mains voltages. So I would say it's just the bad design of the meter that caused your burn!

Quote from Wikipedia

Good quality multimeters designed to meet CAT II and above ratings will include High Rupture Capacity ceramic fuses typically rated at more than 20 kA breaking capacity.[34] They will also include high energy overvoltage MOV (Metal Oxide Varistor) protection, and circuit over-current protection in the form of a Polyswitch.

In this Wikipedia article you can also find this picture of a proper designed multimeter (CAT IV)

  • Category I: used where equipment is not directly connected to the mains
  • Category II: used on single phase mains final sub-circuits
  • Category III: used on permanently installed loads such as distribution panels, motors, and 3-phase appliance outlets
  • Category IV: used on locations where fault current levels can be very high, such as supply service entrances, main panels, supply meters, and primary over-voltage protection equipment

Plus see this nice read about safety categories.