Timeout error trying to lock table in h2
For those having this issue with integration tests (i.e. server is accessing the h2 db and an integration test is accessing the db before calling the server, to prepare the test), adding a 'commit' to the script executed before the test makes sure that the data are in the database before calling the server (without MVCC=true - which I find is a bit 'weird' if it is not enabled by default).
I faced quite the same problem and using the parameter "MVCC=true", it solved it. You can find more explanations about this parameter in the H2 documentation here : http://www.h2database.com/html/advanced.html#mvcc
Yes, you can change the lock timeout. The default is relatively low: 1 second (1000 ms).
In many cases the problem is that another connection has locked the table, and using multi-version concurrency also solves the problem (append ;MVCC=true
to the database URL).
EDIT: MVCC=true
param is no longer supported, because since h2 1.4.200 it's always true for a MVStore engine, which is a default engine.