Hyperref Doesn't link \cite Command
It has been 2 years since this question was asked, but I will write my solution because I had the same problem.
As suggested by many, hyperref
should be imported last. I also tried that but failed to hyperlink my citations in the document. So, the problem is with the ieeeconf.cls
. If you open it with the latex editor you are using you'll see the following:
% 2) Provide a fake nabib command \NAT@parse so that hyperref will not
% interfere with the operation of cite.sty. However, as a result citation
% numbers will not be hyperlinked. Also, natbib will not be able to work
% with IEEEtran. However, this is perhaps the best solution until cite.sty
% and hyperref.sty are able to co-exist with each other.
% It easy enough to override the fake command via:
% \makeatletter
% \let\NAT@parse\undefined
% \makeatother
Here is my example:
\documentclass[letterpaper, 10 pt, conference]{ieeeconf}
\IEEEoverridecommandlockouts
\overrideIEEEmargins % Needed to meet printer requirements.
\usepackage{times} % assumes new font selection scheme installed
\usepackage{amsmath} %assumes amsmath package installed
\usepackage{amssymb} % assumes amsmath
\usepackage[export]{adjustbox}
\usepackage{footnote}
\makeatletter
\let\NAT@parse\undefined
\makeatother
\usepackage{hyperref} %hyperref still needs to be put at the end!
\title{\LARGE \bf
Some Title*
}
\author{Author One$^{1}$, Author Two$^{2}$ % <-this % stops a space
\begin{document}
\maketitle
\thispagestyle{empty}
\pagestyle{empty}
\begin{abstract}
Some Random Abstract.
\end{abstract}
\section{Introduction}
Results from the \cite{a}, \cite{b}, \cite{c} serve as motivation...
\begin{thebibliography}
\bibitem{a} First reference
\bibitem{b} Second reference
\bibitem{c} Third reference
\end{thebibliography}
\end{document}
I just included the three lines suggested in the cls file. As Schweinebacke remarked, this is for the old version of ieeeconf.cls
.
Your code contain several errors. In my MWE below I corrected them. The main errors are marked with <============
.
Some remarks:
- The
hyperref
has to be (except in rare cases) the last package in the preamble. - Your command
\begin{thebibliography}
is not correct. It has to has a length parameter for the labels like\begin{thebibliography}{99}
. - The
\bf
is outdated. Use\textbf{...}
instead or\bfseries
. - I commented your two IEEE commands, they are unknown in the class I have.
- Your command
\author{}
was not closed with a}
. - Define block element is not needed for the MWE (BTW: Why do you use it?)
- Preamble of your MWE contain several packages (
amsmath
,footnote
, ...) not used in your code. Since they are not related to the your problem, you can omit them!
MWE:
\documentclass[letterpaper, 10 pt, conference]{ieeeconf} % IEEEconf
%\IEEEoverridecommandlockouts
%\overrideIEEEmargins % Needed to meet printer requirements.
\usepackage{times} % assumes new font selection scheme installed
\usepackage{amsmath} % assumes amsmath package installed
\usepackage{amssymb} % assumes amsmath
\usepackage{xcolor} % <======================================= for green
\usepackage[export]{adjustbox}
\usepackage{footnote}
\usepackage{hyperref} % <====================== last packge to be called
\hypersetup{linkbordercolor=green}
\title{\LARGE
\textbf{Some Title}*
}
\author{Author One$^{1}$, Author 2$^{2}$} % <================= missing }
\begin{document}
\long\def\/*#1*/{} % Define block comment
\graphicspath{ {Chart and Figures/} }
\maketitle
\thispagestyle{empty}
\pagestyle{empty}
\begin{abstract}
Some Random Abstract.
{\textit{Index Terms}~-- Life Science and Health Care; Mechatronics;
Emerging Topics in Automation}
\end{abstract}
\section{Introduction}
Results from the clinical studies \cite{cervino, c2, c3} serve as
motivation for minimizing patient positioning errors during IGRT in
order to minimize positioning-related uncertainties in cancer dose
treatments, improve tumor control, and reduce toxicity \cite{c4, c5}.
\begin{thebibliography}{99} % <==================== length missing! {99}
\bibitem{cervino} Cervino, L.I., Pawlicki, T., Lawson, J.D., Jiang, S.B., Frame-less and mask-less cranial stereotactic radiosurgery: a feasibility study. Phys. Med. Biol. 55 (2010) 1863-1873.
\bibitem{c2} Xing, L., Dosimetric effects of patient displacement and collimator and gantry angle misalignment on intensity modulated radiation therapy. Radiother Oncol, 2000. 56(1): p. 97-108.
\bibitem{c3} Manning, M.A., et al., The effect of setup uncertainty on normal tissue sparing with IMRT for head-and-neck cancer. Int J Radiat Oncol Biol Phys, 2001. 51(5): p. 1400-9.
\bibitem{c4} Hong, T.S., et al., The impact of daily setup variations on head-and-neck intensity-modulated radiation therapy. Int J Radiat Oncol Biol Phys, 2005. 61(3): p. 779-88.
\bibitem{c5} Den, R.B., et al., Daily image guidance with cone-beam computed tomography for head-and-neck cancer intensity-modulated radiotherapy: a prospective study. Int J Radiat Oncol Biol Phys, 2010. 76(5): p. 1353-9.
\end{thebibliography}
\end{document}
and the result:
I would suggest to use biblatex